Product Highlights

  • E-nside TAAA is the first Pre-Cannulated, inner branch-based, OFF-THE-SHELF solution for thoracoabdominal aneurysms accessible on the market.
  • Inner branches: More versatility. More anatomies. More patients.
  • Pre-cannulation is designed to minimize fluoroscopy, implantation time, and contrast media necessary to finalize the procedure.

Product Overview

1
2
3
4

1. ASYMMETRICAL COMPRESSION SPRINGS

Elite7

Designed to maintain patency of the branches as well as avoid longitudinal compressions during catheterization of the target vessels.

2. FIXATION SEAM

Enside5

The proximal fixation of the inner branches allows longitudinal stability and support during cannulation of the target vessels.

3. ENLARGED, ELLIPTICAL OUTLET

Enside4

Re-designed oval-shaped outlets to allow for greater flexibility of the covered stents.

4. MIGRATION REDUCTION

Enside6

A thin 0.1 mm PET thread added inside each inner branch designed to enhance the friction of any covered stent to help minimize migration.

Enside3
1
2
3
4

1. PROXIMAL CLASPING SYSTEM

Although fully covered, the asymmetrical proximal spring allows blood flow, as well as guide wires and catheters, to gain access to the top of stent graft even with the tip capture still in place.

Enside Call Out 1

2. FIXATION

Knurled cap and tactile marker for fixation during the procedure.

Enside Call Out 3

3. DEPLOYMENT HANDLE

Proven Squeeze-to-Release mechanism to ensure low friction, controlled deployment of the stent graft.

Enside Call Out 4

4. PRE-CANNULATION

Four 0.018“ (I.D.) tubes ensure access to the inner branches of the stent graft and by means of a through & through implantation technique provide convenient access for the covered stents.

Enside Call Out 2

Enside DS

Clinical Evidence

INBREED

Two Year Outcomes following Off-the-Shelf Inner Branch Endograft Implantation for the Treatment of
Complex Abdominal and
Thoraco-abdominal Aortic Aneurysm:
Analysis from the Multicentre
ItaliaN Branched Registry of E-nside EnDograft (INBREED).

 

 

 

 2-Year Follow-Up Results (143 Patients)

 

 

 

*4 cases of type Ia endoleak only, 2 of them ended in a graft distal migration, noting that 1 of them had initial signs of aneurysmal wall evolution.
**VA: Visceral arteries
***RA: Renal arteries

 

 

 

Inner vs. Outer Branch Performance: Key Insights1

Product Animation

Additional Resources

Explore additional resources for E-nside TAAA below. For further information or to contact a sales associate in your area, contact us.

Sizing Sheet

Implantation Poster

  1. Karaolanis GI, Makaloski V, Jungi S, Weiss S, Kotopoulos K, Chaikhouni B, et al. Endovascular repair of pararenal and thoracoabdominal aortic aneurysms with inner and outer off-the-shelf multibranched endografts: a systematic review and meta-analysis. J Vasc Surg. 2025 Jan;81(1):251-260.e3. doi: 10.1016/j.jvs.2024.08.013. Epub 2024 Aug 13.
  2. Michele Piazza, Francesco Squizzato, Giovanni Pratesi, Antonio Bozzani, Wassim Mansour, Emanuele Gatta, Giacomo Isernia, Gioele Simonte, Michele Antonello, INBREED Investigators. European Journal of Vascular & Endovascular Surgery, YEJVS 9952, August 2025. https://doi.org/10.1016/j.ejvs.2025.08.042

All products and indications are not available/approved in all markets. All trademarks are owned by Artivion, Inc. or its subsidiaries. On-X Life Technologies, Inc., Jotec GmbH, and Ascyrus Medical GmbH are wholly owned subsidiaries of Artivion, Inc. MWENG0081.000 (2026-06)

JOTEC GmbH, Lotzenäcker 23, 72379 Hechingen, Germany