E-vita® Open Neo
HYBRID STENT GRAFT SYSTEM
Made to Fit Your Patients.
Made to Fit You.
Product Highlights
Based on over ten years of clinical experience, E-vita Open Neo is the next-generation hybrid graft system for aortic arch and descending thoracic aorta repair with the Frozen Elephant Trunk technique.
ADAPTING TO PATIENT’S DISEASE
- Each disease requires unique technique and oversizing strategies. E-vita Open Neo has been created with three stent graft configurations and dedicated designs of the vascular and stent graft sections.
- The three diameters of the vascular section allow for reproducible anastomosis. The full range of options of the stent graft section provides adequate oversizing for both aneurysms and dissections.1
CONTROL IN YOUR HANDS
- The new compact delivery system allows easy positioning of the device, and deployment can be performed in a controlled fashion with progressive expansion of the stent graft section.1
Product Overview
STRAIGHT
CONFIGURATION
Island Technique
Collar Anastomosis in Zone 2/3
BRANCHED
CONFIGURATION
Sequential Anastomoses
Collar Anastomosis in Zone 1/2/3
TRIFURCATED
CONFIGURATION
Sequential Anastomoses
Collar Anastomosis in Zone 0/1
1. RELEASE TRIGGER & HANDLE
For controlled deployment.
2. PROTECTIVE FLAP
Can be left in place to pre-shape the shaft, or removed to utilize the guide wire of choice.
3. SHAPEABLE SHAFT
To adapt to patient anatomy.
4. ATRAUMATIC TIP
For smooth advancement and withdrawal.
5. OVER-THE-WIRE DESIGN
For trackability thanks to the pearl technology of the shaft.
6. NITINOL RELEASE WIRE
Clinical Evidence
E-vita Open Neo: A Patient-Tailored Approach to the Frozen Elephant Trunk Technique1
Dr. Wong’s experience:
- The E-vita Open Neo covers a lot of the unmet needs of FET.
- Z-shape stent design could reduce the risk of dSINE as it exerts less focal stress to the aortic wall.
- The new delivery system is compact and easy to use compared with the former systems.
E-vita Open Neo: A Patient-Tailored Approach to the Frozen Elephant Trunk Technique1
Prof. Song’s experience:
- Trifurcated configuration is easier and safer.
- The trifurcated type has an advantage in zone 0 or 1 anastomoses over the branched type in regard to angulation and space of the head vessel branch.
.
E-vita Open Neo Hybrid Stent Graft: A New Frontier for Total Arch Replacement 2
-
A versatile system for each patient’s needs.
-
Curative option for aortic dissections as well as aneurysms.
-
Facilitates distal extension to compete for the treatment endovascularly.
The Frozen Elephant Technique Using a Novel Hybrid Prosthesis for Extensive Aortic Arch Disease: A Multicentre Study3
- Safe and effective use.
- The new device features may reduce cardiac arrest and decrease the rate of SCI.
- Trifurcated configuration is easier and faster, also allowing for minimally invasive surgery.
Product Video
E-vita Open Neo is the next-generation hybrid stent graft system for aortic arch and descending thoracic aorta repair with Frozen Elephant Trunk Technique.
Additional Resources
Explore additional resources for E-vita Open Neo below. For further information or to contact a sales associate in your area, contact us.
Product Highlights
- E-vita Open Neo Hybrid Stent Graft System Instructions for Use.
Clinical Evidence
- Wong et.al. (2022). E-vita Open Neo: A Patient-Tailored Approach to the Frozen Elephant Trunk Technique. Endovascular Today Featured Technology – May 2022.
- Rorris et.al, (2022). E-vita Open Neo Hybrid Stent Graft: A New Frontier for Total Arch Replacement. Ann Vasc Surg 2022; -: 1–7.
- Ahmad et.al.(2023). The Frozen Elephant Technique Using a Novel Hybrid Prosthesis for Extensive Aortic Arch Disease: A Multicentre Study. Adv Ther (2023).
All products and indications are not available/approved in all markets. All trademarks are owned by Artivion, Inc. or its subsidiaries. On-X Life Technologies, Inc., Jotec GmbH, and Ascyrus Medical GmbH are wholly owned subsidiaries of Artivion, Inc. MLENG1590.000. (2023-04)
JOTEC GmbH, Lotzenäcker 23, 72379 Hechingen, Germany |